Home โ†’ Resources โ†’ Smoke & CO Alarm Requirements

Landlord Compliance

Maryland Smoke Detector & CO Alarm Requirements for Landlords (2026)

Updated June 2026 ยท By HBAY Property Management ยท Baltimore & Howard County, MD

Maryland law requires landlords to install and maintain working smoke alarms and carbon monoxide detectors in all rental properties. Failure to comply is a misdemeanor โ€” not just a code violation โ€” and can carry fines up to $1,000. Here's exactly what you need to have installed.

Smoke Alarm Requirements

Maryland's smoke alarm law (Public Safety Article, Title 9, Subtitle 1) applies statewide including Baltimore and Howard County. Landlords must install:

Where Smoke Alarms Must Be Installed

Alarm Type Requirements

New for Short-Term Rentals (Effective October 1, 2026)

Maryland's SB 624 (pending signature) will require short-term rentals to have interconnected smoke alarms and fire extinguishers. If you rent on Airbnb or VRBO, plan for this requirement before October 2026.

Carbon Monoxide (CO) Alarm Requirements

Maryland law (Public Safety Article, Title 12) requires CO alarms in rental properties that have:

Where CO Alarms Must Be Installed

โš ๏ธ Almost Every Baltimore/Howard County Rental Needs CO Alarms

Most Maryland homes have gas furnaces, gas water heaters, or gas stoves โ€” all of which trigger the CO alarm requirement. When in doubt, install them. The cost ($20โ€“$40 per alarm) is minimal compared to the liability exposure.

Combination Alarms

A single combination smoke + carbon monoxide alarm can satisfy both requirements as long as it meets UL 217 and UL 2034 standards. This is the most practical solution for most rental properties.

Landlord Responsibilities

ResponsibilityWhoWhen
Install all required alarmsLandlordBefore tenant moves in
Verify alarms are workingLandlordAt start of each lease
Provide written maintenance instructionsLandlordAt start of each lease
Repair/replace defective alarmsLandlordWithin 5 days of written notice from tenant
Acknowledge tenant's written repair notice in writingLandlordUpon receipt
Test alarms periodicallyTenantOngoing (after move-in)
Report defective alarms to landlordTenantIn writing when discovered

Hard-of-Hearing Tenants

If a tenant who is deaf, deafblind, or hard of hearing provides a written request, the landlord must install an appropriate alarm notification appliance โ€” typically a strobe light or bed shaker system. The landlord cannot require the tenant to pay for this or provide documentation of their disability.

Penalties for Non-Compliance

Baltimore County Inspection Requirement

When applying for a Baltimore County rental license, your home inspector will verify that smoke and CO alarms are properly installed. This is a required part of the inspection checklist. Baltimore County also requires a Carbon Monoxide Affidavit as part of the rental license application.

Practical Checklist for Landlords